Bottom Flooring. | 18mm cement bonded fiber sheets. (100% water, termite & dimensional proof with 1.2MM Thk vinyl carpet.) |
Aluminum Windows - 2 nos.
| Double Shutter sliding Aluminum Powder coated Windows with 4mm Glass for all windows. Safety grills from outside and monsoon shed on top of the windows |
Door - 1 no.
| Constructed of Rigid Steel Frame with proper locking system. |
Insulation | Thermocol Insulation-25mm on sides and 50mm on top. |
Wiring | All wiring shall be concealed type & shall be insulated copper wire (FR grade) of ISI Polycab/Fortune Art/Ronaldo/Finolex. |
Electrical Fittings | All electrical fitting in the portable cabin shall be 220 -240 V, AC 50Hz. 1) Tubes lights - 3 nos. 2) Door Light- 1 no. 3) Fan - 2 nos. 4) 5 amp Socket Points - 4 nos. 5) 16 amp A.C Point - 1 no. 6) Earth leakage circuit breaker (ELCB) at the INPUT JUNCTION for additional SAFETY. |
Outside Painting | Complete chemical cleaning done on the cabin and painting done with 2 coats of epoxy primer and two coats of Chlorinated Rubber paint - Make ASIAN/BERGER. |
Hooks | Specially formed hooks for easy lifting and shifting. |